| Products ....
|
|
HIGHLIGHTS OF ASTM SPECIFICATIONS
FOR STAINLESS STEEL TUBES & PIPES
|
|
|
|
Specification
|
Allowable Outside Diameter
|
Allowable Wall
|
Exact Length
|
Testing
|
|
.
|
Variations in mm
|
.
|
Tickness Variations
|
Tolerances in mm
|
Product Analysis
|
|
.
|
Diameter
|
Over
|
Under
|
Over %
|
Under %
|
Over
|
Under
|
.
|
|
.
|
25.4
|
0.05
|
0.20
|
12.5
|
-12.5
|
3.2
|
0
|
Reverse Flattening test
|
|
ASTM A-270
|
38.1
|
0.05
|
0.20
|
12.5
|
-12.5
|
3.2
|
0
|
100% Hydrostatic test
|
|
Seamless & Welded
|
50.8
|
0.05
|
0.28
|
12.5
|
-12.5
|
3.2
|
0
|
External Polish on all tubes
|
|
Sanitary Tubing
|
63.5
|
0.05
|
0.28
|
12.5
|
-12.5
|
3.2
|
0
|
.
|
|
.
|
76.2
|
0.08
|
0.30
|
12.5
|
-12.5
|
3.2
|
0
|
Refer to ASTM A - 270
|
|
.
|
101.6
|
0.08
|
0.38
|
12.5
|
-12.5
|
3.2
|
0
|
.
|
|
.
|
Under 25.4
|
0.1016
|
0.1016
|
10
|
-10
|
3.175
|
0
|
Tension Test
|
|
ASTM A - 249
|
24.4-38.1 incl.
|
0.1524
|
0.1524
|
10
|
-10
|
3.175
|
0
|
Flattening Test
|
|
Welded Boiler
|
38.1-50.8 excl.
|
0.2032
|
0.2032
|
10
|
-10
|
3.176
|
0
|
Flare Test/Flange Test
|
|
Superheater
|
50.8-63.5 excl.
|
0.2540
|
0.2540
|
10
|
-10
|
4.76
|
0
|
* Reverse Bend Test
|
|
Heat
|
63.5-76.2 excl.
|
0.3048
|
0.3048
|
10
|
-10
|
4.76
|
0
|
Hardness Test
|
|
Exchanger and
|
76.2-101.6 incl.
|
0.3810
|
0.3810
|
10
|
-10
|
4.76
|
0
|
100% Hydrostatic Test
|
|
Condenser Tubes
|
.
|
.
|
.
|
Minimum Wall tubes
|
.
|
.
|
* Reverse Flattening Test
|
|
.
|
.
|
.
|
.
|
18% - 0 available
|
.
|
.
|
Refer to ASTM A - 270
|
|
.
|
.
|
.
|
.
|
on request
|
.
|
.
|
.
|
* wherever applicable
|
|
.
|
13.7-48.3 incl.
|
0.40
|
0.79
|
Minimum Wall 12.5 %
|
6.4
|
0
|
Tenstion Test
|
|
ASTM A - 312
|
48.3-114.3 incl.
|
0.79
|
0.79
|
Under nominal wall
|
6.4
|
0
|
Flattening Test
|
|
Seamless & Welded
|
114.3-220. Incl.
|
1.60
|
0.79
|
specified
|
.
|
6.4
|
0
|
100% Hydrostatic Test
|
|
.
|
.
|
.
|
.
|
.
|
.
|
(Normally Random
|
Refer to ASTM A - 530
|
|
.
|
.
|
.
|
.
|
.
|
.
|
lengths ordered)
|
.
|
|
.
|
Upto 12.7
|
0.13
|
0.13
|
15
|
-15
|
3.2
|
0
|
Flare Test
|
|
.
|
12.7-38.1
|
0.13
|
0.13
|
10
|
-10
|
3.2
|
0
|
Flange Test (Welded only)
|
|
ASTM A - 269
|
38.1-88.9 excl.
|
0.25
|
0.25
|
10
|
-10
|
4.8
|
0
|
Hardness Test
|
|
Seamless & Welded
|
88.9-139.7 excl.
|
0.38
|
0.38
|
10
|
-10
|
4.8
|
0
|
Reverse Flattening test
|
|
Service
|
139.7-203.2 excl.
|
0.76
|
0.76
|
10
|
-10
|
4.8
|
0
|
(welded only)
|
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
100% Hydrostatic test
|
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
Refer to ASTM A - 269
|
|
.
|
Under 25.4
|
0.1016
|
0.1016
|
20
|
0
|
3.175
|
0
|
Tension Test
|
|
ASTM A - 213
|
24.4-38.1 incl.
|
0.1524
|
0.1524
|
20
|
0
|
3.175
|
0
|
Flattening Test
|
|
Seamless Boiler,
|
38.1-50.8 excl.
|
0.2032
|
0.2032
|
22
|
0
|
3.176
|
0
|
Flare Test
|
|
Superheaterand
|
50.8-63.5 excl.
|
0.2540
|
0.2540
|
22
|
0
|
3.76
|
0
|
Hardness Test
|
|
Heat Exchanger
|
63.5-76.2 excl.
|
0.3048
|
0.3048
|
22
|
0
|
4.76
|
0
|
100% Hydrostatic test
|
|
Tubes
|
76.2-101.6 incl.
|
0.3810
|
0.3810
|
22
|
0
|
4.76
|
0
|
Refer to ASTM A - 450
|
|
.
|
Under 12.7
|
0.13
|
0.13
|
15
|
-15
|
3.2
|
0
|
Tension Test, Flare Test
|
|
ASTM A - 268
|
12.7-38.1 excl.
|
0.13
|
0.13
|
10
|
-10
|
3.2
|
0
|
Flange Test (ERW only)
|
|
Seamless & Welded
|
38.1-88.9 excl.
|
0.25
|
0.15
|
10
|
-10
|
4.8
|
0
|
Hardness Test
|
|
Ferrtic Stainless
|
88.9-168.3 excl.
|
0.38
|
0.38
|
10
|
-10
|
4.8
|
0
|
Reverse Flattening test
|
|
Steel tubes
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
100% Hydrostatic test
|
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
Transvers tension test,
|
|
ASTM A - 358
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
Transverse guided bend
|
|
For welded big
|
For all size
|
0.5%
|
-0.5%
|
No
|
-0.3
|
Customer's
|
.
|
test. Hydrostatic Test,
|
|
Diameter Pipes
|
.
|
.
|
.
|
LIMIT
|
mm
|
Specification
|
radiographic examition (as
|
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
specified) dye penetrant
|
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
(optional).
|
.
|
|
ASTM A - 688
|
Under 25.4
|
0.1016
|
0.1016
|
20
|
0 (for Min
|
3 to 13
|
0
|
Tension, Hardness,
|
|
For welded Feed
|
.
|
.
|
.
|
.
|
wall thk)
|
.
|
.
|
corrosion, Reversebend
|
|
water heater
|
.
|
.
|
.
|
.
|
10(for Avg
|
.
|
.
|
Flange, Flattening,
|
|
U' Tubes
|
.
|
.
|
.
|
.
|
wall thk)
|
.
|
.
|
Hydrostatic Test, Pneumatic
|
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
.
|
Test, Non Destructive Test
|
|
|